STARTING FLUID (ETHER) CYLINDER REPLACEMENT. - Continued
ETHER START THERMOSTAT REPLACEMENT. - Continued

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  710    711    712    713    714  715  716    717    718    719    720  
img
. . . . . . . . . . . . . .
TM 5-2420-230-24-1
d. Follow-On Maintenance.
Starting fluid cylinders are typically stored with the threaded end up, which is opposite of its installed
position. Therefore, when a new cylinder is first installed, allow the contents to settle for approximately
15 to 20 min. Failure to comply may result in damage to equipment.
(1)
Functionally test ether start while starting engine (TM 5-2420-230-10).
(2)
Shut OFF engine (TM 5-2420-230-10).
(3)
Remove "Do Not Operate" tag from ignition switch (TM 5-2420-230-10).
END OF TASK
20-16. ETHER START THERMOSTAT REPLACEMENT.
This Task Covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Test Equipment
References
None
None
Tools and Special Tools
Equipment Conditions
Tool kit, common no. 2, Item 36, Appendix B
TM or Para
Condition Description
Tool kit, general mechanics, Item 38, Appendix B
Para 12-31
Remove washer bottle.
Materials/Parts
Drawings Required
Connector, wire, Item 39.1, Appendix D
TM 5-2420-230-24P Figure 207
Tags, identification, Item 63, Appendix C
Terminal, Item 267.1, Appendix D
Estimated Time to Complete Task
Ties, cable, Item 68, Appendix C
Refer to MAC in Appendix B
Personnel Required
MOS 62B, Construction Equipment Repairer
Change 1