c. Follow-On Maintenance.
(1)
Install hydraulic reservoir step plate (Para 13-15).
(2)
Close battery box (TM 5-2420-230-10).
(3)
Plug in electrical outlet and ensure battery trickle charger and block heater are operating properly
(TM 5-2420-230-10).
(4)
Unplug electrical outlet if ambient temperature does not require its use (TM 5-2420-230-10).
END OF TASK
20-19. ELECTRICAL OUTLET REPLACEMENT.
This Task Covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Test Equipment
References
None
None
Equipment Conditions
Tools and Special Tools
TM or Para
Condition Description
Tool kit, common no. 2, Item 36, Appendix B
TM 5-2420-230-10
Battery box opened.
Tool kit, general mechanics, Item 38, Appendix B
TM 5-2420-230-10
Electrical outlet unplugged.
Para 13-15
Hydraulic reservoir step plate
Materials/Parts
removed.
Connector, wire, Item 39.2, Appendix D (3)
Tags, identification, Item 63, Appendix C
Drawings Required
Tape, electrical, Item 65, Appendix C
TM 5-2420-230-24P Figure 207
Ties, cable, Item 68, Appendix C
Estimated Time to Complete Task
Refer to MAC in Appendix B
Personnel Required
MOS 62B, Construction Equipment Repairer