DTC 13306.02 - ABNORMAL EXCAVATOR OPERATION AND TESTS (EEPROM)
DTC 13308.02 - ABNORMAL CAN COMMUNICATION

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  927    928    929    930    931  932  933    934    935    936    937  
img
TM 5-3805-294-23-1
0134
Table 1. DTC 13306.02 - Abnormal Excavator Operation And Tests (EEPROM) - Continued.
Test or Inspection
Corrective Action
Malfunction
3.
Turn the key switch to the OFF
1.
If DTC 13306.02 is still active,
position (TM 5-3805-294-10).
replace monitor controller.
(Volume 5, WP 0794)
(Volume 4, WP 0518) Restore
machine to original condition.
Clear and refresh DTCs.
(Volume 3, WP 0362)
2.
If DTC 13306.02 is not active,
problem corrected. Restore
machine to original condition.
Clear and refresh DTCs.
(Volume 3, WP 0362)
END OF WORK PACKAGE