Table 1. DTC 13311.03 - Fuel Level Sensor Short Circuit - Continued.
Test or Inspection
Corrective Action
Malfunction
Visually inspect monitor
1.
If damaged or has loose pins,
5.
Monitor Controller
controller for damage and
replace monitor controller.
Has Damage or
loose pins. (Volume 5,
Loose Pins.
(Volume 4, WP 0519) Restore
WP 0800, Figure 218)
machine to original condition.
Clear and refresh DTCs.
(Volume 3, WP 0362)
2.
If not damaged and does not
have loose pins, proceed to
Malfunction 6.
Measure resistance (Volume
1.
If continuity is present,
6.
Shorted Circuit
proceed to Malfunction 7.
Between Connector
3, WP 0369) between
X21 Socket 2 and
connector X21 socket 2
2.
If continuity is not present,
Ground.
(Volume 5, WP 0800, Figure
replace monitor controller.
88) and known good ground.
(Volume 4, WP 0518) Restore
Note reading.
machine to original condition.
Clear and refresh DTCs.
(Volume 3, WP 0362)
1.
Disconnect the following:
7.
Connector X3 Has
Damage or Loose
a. Connector X3. (Volume
Pins/Sockets.
5, WP 0800, Figure 84)
b. Connector X4. (Volume
5, WP 0800, Figure 85)
c. Connector X41.
(Volume 5, WP 0800,
Figure 102)
d. Connector X42.
(Volume 5, WP 0800,
Figure 103)
2.
Unmount and reposition the
cab wiring harness connectors
for service. (Volume 3,
WP 0312)