TM 5-3805-294-23-1
0135
Table 1. DTC 13308.02 - Abnormal CAN Communication - Continued.
Test or Inspection
Corrective Action
Malfunction
1.
19.
Short Circuit
proceed to Malfunction 20.
Between Connector
3, WP 0369) between
X20 Socket 7 And
connector X20 socket 7
2.
Connector X19
(Volume 5, WP 0800, Figure
proceed to Malfunction 22.
Socket 16.
87) and connector X19 socket
16. (Volume 5, WP 0800,
Figure 86) Note reading.
1.
Disconnect connector X24.
20.
Connector X24 Has
Damage or Loose
(Volume 5, WP 0800, Figure
Sockets/Pins.
91)
2.
Visually inspect connector X24
1.
If damaged or has loose
for damage or loose sockets/
sockets/pins, replace monitor
pins.
controller wiring harness for
pin side (Volume 4, WP 0519)
or replace cab wiring harness
for socket side. (Volume 4,
WP 0504) Restore machine to
original condition.
2.
If not damaged and does not
have loose sockets/pins,
proceed to Malfunction 21.
1.
21.
Short Circuit
monitor controller wiring
Between Connector
3, WP 0369) between
harness. (Volume 4,
X20 Socket 7 And
connector X20 socket 7
Connector X19
WP 0519) Restore machine to
(Volume 5, WP 0800, Figure
Socket 16 With
original condition.
87) and connector X19 socket
Connector X24
16. (Volume 5, WP 0800,
2.
Disconnected.
Figure 86) Note reading.
replace cab wiring harness.
(Volume 4, WP 0504) Restore
machine to original condition.
1.
22.
Short Circuit
proceed to Malfunction 23.
Between Connector
3, WP 0369) between
X20 Socket 6 and
connector X20 socket 6
2.
Connector X19
(Volume 5, WP 0800, Figure
replace monitor controller.
Socket 16.
87) and connector X19 socket
(Volume 4, WP 0518) Restore
16. (Volume 5, WP 0800,
machine to original condition.
Figure 86) Note reading.
1.
Disconnect connector X24.
23.
Connector X24 Has
Damage or Loose
(Volume 5, WP 0800, Figure
Sockets/Pins.
91)
0135-6