Figure 5. Ground Terminal W36 and Security Alarm Connections
Figure 9. Main Controller Connections.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  111    112    113    114    115  116  117    118    119    120    121  
img
.
TM 5-3805-294-23-4
0504
REMOVAL - Continued
18.
Disconnect cab wiring harness W1 at connection H3 (Figure 7, Item 39) from monitor warning alarm wiring
(Figure 7, Item 40).
40
39
44
45
41
42
46
43
47
32
HYEX01070
Figure 7. Monitor Alarm, Speakers, and Ground Terminal W37 Connections.
19.
Remove bolt (Figure 7, Item 41), washer (Figure 7, Item 42), and cab wiring harness W1 ground terminal W37
(Figure 7, Item 43) from bracket (Figure 7, Item 32).
20.
Disconnect cab wiring harness W1 at connection B25 (Figure 7, Item 44) from right speaker wiring (Figure 7,
Item 45).
21.
Disconnect cab wiring harness W1 at connection B26 (Figure 7, Item 46) from left speaker wiring (Figure 7,
Item 47).
22.
Disconnect cab wiring harness W1 at connection X32 (Figure 8, Item 48) from information controller (Figure
8, Item 49).
51
52
48
49
50
HYEX00672
Figure 8. Information Controller and Power Converter Connections.