73.
Connect wiring harness connector B18 (Figure 49, Item 9) to fuel level sensor (Figure 49, Item 10).
74.
Install cable (Figure 49, Item 8) with three clips (Figure 49, Item 7).
75.
Connect two wiring harness connectors E1 (Figure 49, Item 5) to drive light terminals (Figure 49, Item 6).
CAUTION
B40 hydraulic oil temperature sensor connector has a small metal retaining clip that is spring
loaded and if lost can cause damage to machine. Failure to comply may result in damage to
equipment.
76.
Connect wiring harness connector B40 (Figure 50, Item 3) to hydraulic oil temperature sensor (Figure 50, Item
4).