7.
Install brackets (Figure 5, Item 29) and (Figure 5, Item 26) to frame (Figure 5, Item 30) with four washers (Figure
5, Item 28) and bolts (Figure 5, Item 27).
NOTE
If HYEX is equipped with a Supplemental Armor Set, install CCTV power supply to
bracket (Figure 5, Item 26) using procedure found in TM 5-3805-295-13&P.
If splitter wiring harness removed, perform Steps (8) through (13).
8.
Install black wire splitter wiring harness (Figure 5, Item 22) to splitter wiring harnesses connector (Figure 5,
9.
Connect black wire splitter wiring harness connector (Figure 5, Item 20) to overload alarm wiring harness
connector (Figure 5, Item 21).
10.
Connect black wire splitter wiring harness connector (Figure 5, Item 18) to hydraulic hose reel wiring harness
connector (Figure 5, Item 19).
11.
Install red wire splitter wiring harness (Figure 5, Item 17) to splitter wiring harnesses connector (Figure 5, Item
12.
Connect red wire splitter wiring harness connector (Figure 5, Item 15) to overload alarm wiring harness
connector (Figure 5, Item 16).
13.
Connect red wire splitter wiring harness connector (Figure 6, Item 13) to hydraulic hose reel wiring harness
connector (Figure 6, Item 14).
0554-6