TM 5-2420-230-24-1
b. Installation.
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment and injury or death to personnel may occur.
NOTE
Install cable ties as necessary.
(0.1) If remove, install new O-ring (11) on potentiometer plate (9).
(1)
If required, install potentiometer plate (9) on
FEL arm (10) with four bolts (8).
(2)
Install potentiometer (7) with two screws (5)
and washers (6).
(3)
Install dust cover (4) with four bolts (2) and
(4)
Connect potentiometer switch (1).
c. Follow-On Maintenance.
(1)
Start engine and perform hydraulic
(2)
(3)
Remove "Do Not Operate" tag from ignition
END OF TASK
Change 1
12-80