TEST FUEL INJECTION NOZZLES
INJECTION NOZZLE OPENING PRESSURE SPECIFICATIONS

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  386    387    388    389    390  391  392    393    394    395    396  
img
.
TM 5-3805-281-24-2
Fuel System
PERFORM OPENING PRESSURE TEST
1. Connect injection nozzle to D01109AA Nozzle Tester
(Y900) (A), using No. Y900-2A Fuel Line (B) and
Y900-7 and Y90-15 Straight Adapters (C). Y900-21 90
Adapter may also be used. Place a glass beaker (D)
around nozzle.
2. Pump handle several times to flush out nozzle fittings.
Tighten fittings.
3. Expel air from nozzle by operating pump handle
several strokes. Then raise pressure until valve opens.
4. Recheck by completely releasing pressure, then
gradually building pressure until valve opens.
IMPORTANT: Nozzle tester should be checked
periodically for accuracy.
Testing Nozzle Opening Pressure
A--Nozzle Tester
B--Fuel Line
C--Adapter
D--Glass Beaker
RG,RG34710,1304
1923OCT971/1
11-390