Figure 1. Starter Positive Cable Removal
Figure 2. Starter Positive Cable Installation

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  311    312    313    314    315  316  317    318    319    320    321  
img
TM 5-3805-294-23-4
0527
REMOVAL - Continued
3.
Remove bolt (Figure 1, Item 6), washer (Figure 1, Item 7), clamp (Figure 1, Item 8), and starter positive cable
(Figure 1, Item 9) from frame (Figure 1, Item 4).
4.
Remove bolt (Figure 1, Item 10), washer (Figure 1, Item 11), starter positive cable (Figure 1, Item 9), machine
wiring harness connector (Figure 1, Item 12), and slave receptacle positive cable (Figure 1, Item 13) from
battery relay K19 (Figure 1, Item 14).
5.
Remove bolt (Figure 1, Item 15), washer (Figure 1, Item 16), clamp (Figure 1, Item 17), and starter positive
cable (Figure 1, Item 9) from frame (Figure 1, Item 18).
6.
Remove bolt (Figure 1, Item 19), washer (Figure 1, Item 20), clamp (Figure 1, Item 21), and starter positive
cable (Figure 1, Item 9) from frame (Figure 1, Item 18).
7.
Remove bolt (Figure 1, Item 22), washer (Figure 1, Item 23), clamp (Figure 1, Item 24), and starter positive
cable (Figure 1, Item 9) from frame (Figure 1, Item 18).
8.
Remove bolt (Figure 1, Item 25), washer (Figure 1, Item 26), clamp (Figure 1, Item 27), and starter positive
cable (Figure 1, Item 9) from frame (Figure 1, Item 18).
9.
Remove bolt (Figure 1, Item 28), washer (Figure 1, Item 29), clamp (Figure 1, Item 30), and starter positive
cable (Figure 1, Item 9) from frame (Figure 1, Item 18).
10.
Lift boot (Figure 1, Item 31) and slide away from starter positive cable (Figure 1, Item 9).
11.
Remove nut (Figure 1, Item 32), lockwasher (Figure 1, Item 33), starter protection wiring harness connector
(Figure 1, Item 34), and starter positive cable (Figure 1, Item 9) from starter motor solenoid terminal (Figure
1, Item 35). Discard lockwasher.
12.
Remove starter positive cable (Figure 1, Item 9) from frame (Figure 1, Item 18).
END OF TASK
INSTALLATION
1.
Route starter positive cable (Figure 2, Item 9) to frame (Figure 2, Item 18).
0527-3