Figure 2. Starter Protection Wiring Harness Removal From Relays
Figure 3. Starter Protection Wiring Harness Installation To Relays

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  318    319    320    321    322  323  324    325    326    327    328  
img
TM 5-3805-294-23-4
0528
REMOVAL
18.
Remove nut (Figure 2, Item 51), lockwasher (Figure 2, Item 52), starter protection wiring harness connector
(Figure 2, Item 53), and washer (Figure 2, Item 54) from starter relay terminal (Figure 2, Item 55). Discard
lockwasher.
19.
Remove nut (Figure 2, Item 56), lockwasher (Figure 2, Item 57), starter protection wiring harness connector
(Figure 2, Item 58), and washer (Figure 2, Item 59) from starter relay terminal (Figure 2, Item 60). Discard
lockwasher.
NOTE
Make note of wiring harness routing prior to and during removal to ensure proper installation.
20.
Remove starter protection wiring harness (Figure 2, Item 34) from machine (Figure 2, Item 61).
END OF TASK
INSTALLATION
1.
Route starter protection wiring harness (Figure 3, Item 34) through machine (Figure 3, Item 61) as noted prior
to removal.